Features |
parameter |
800E |
800EH |
Application occasion |
|
Smart Meter |
Power quality analysis type |
Real-time measurement |
Voltage |
V1,V2,V3,VlNavg,V12,V23,V31,VLLavg |
● |
● |
Current |
I1,I2,I3,Iavg |
● |
● |
Active power |
P1,P2,P3,Psum |
● |
● |
Reactive power |
Q1,Q2,Q3,Qsum |
● |
● |
inspecting power |
S1,S2,S3,Ssum |
● |
● |
Power factor |
PF1,PF2,PF3,PF |
● |
● |
frequency |
F |
● |
● |
Electricity |
Active energy |
EP imp,EP exp,EP total,EP net |
● |
● |
Reactive energy |
EQ imp,EQ exp,EQ total,EQ net |
● |
● |
Time-sharing power |
EPF; 6 time zones, 12 periods in each time zone, 4 rates for this month, last month, EP imp, EP exp, EQ imp, EQ exp |
|
● |
Power quality |
Unbalance |
Voltage three-phase, current three-phase |
|
● |
Voltage harmonic distortion rate |
THD V1,THD V2,THD V3,THD Vavg |
●/◎ |
● |
Current harmonic distortion rate |
THD I1,THD I2,THD I3,THD Iavg |
●/◎ |
● |
Voltage harmonic content rate |
Voltage of each phase, 2-63 times; spectrogram and division value, odd times for each phase, even times for each phase |
|
● |
Current harmonic content rate |
2-63 times for each phase; spectrogram and division value, odd times for each phase, even times for each phase |
|
● |
Advanced power quality analysis |
Voltage swells and drops |
|
● |
Telephone interference coefficient of each phase voltage |
THFF |
|
● |
K factor of each phase current |
KFactor |
|
● |
Advanced power quality analysis |
Voltage swells and drops |
|
● |
Call the police |
Over-limit alarm |
16 channels, optional parameters, logical comparison preset value, delay time setting, DO output can be set |
● |
● |
Wave recording |
Real-time waveform |
Each phase voltage, each phase current, the shortest 78us transient |
●/- |
● |
Waveform capture |
Manual/condition capture for each phase voltage, manual/condition capture for each phase current |
|
● |
Number of records |
10 pieces |
|
● |
data record |
record |
DI state change and time SOE20 records |
|
● |
alarm record |
16 pieces |
|
● |
communication |
Basic RS485 |
MODBUS-RTU SLAVE |
● |
● |
Additional RS485 |
MODBUS-RTU SLAVE |
|
◎ |
Innovative function |
Status Bar |
Status bar displays date, clock, F, PF, EP total |
● |
● |
Infrared |
Infrared sensor based on PIR technology can control the back and security alarm detection |
● |
● |
ISP |
Online software upgrade |
● |
● |
HMI |
3.2-inch TFT true color, wide temperature range of -25℃~+70℃; original four-key soft key operation; Chinese and multiple languages |
● |
● |
LCD liquid crystal display |
◎ |
- |
I/O |
K4S2 |
Passive dry contact DI, SCR SO; standard 4DI2SO |
◎ |
● |
K8S6 |
Up to 8DI4DO |
|
◎ |
Ax |
Up to 2 channels of 4-20mA AO analog |
◎ |
◎ |
Px |
Up to 2 power pulse outputs |
|
◎ |
Dx |
Up to 4 relay outputs |
|
◎ |
Legend ● Standard ◎ Optional |